Home Categories Send inquiry

MD-EL Electromagnetic Flowmeter

Application:

Clean water &sewage   Electricity production &distribution   Chemical & industrial pharmacy   Food industry

Technical characteristics:

1. No moving parts and no wear 2. The measurement range of the process is 1: 100 3. No clear section or flow enhancement device 4. Measuring the flow rate of various conductive liquids 5. Measurement results are not affected by physical properties such as temperature, pressure, viscosity, and density 6. Strong corrosion resistance and wear resistance 7. Measures forward / reverse flow 8. Large LCD screen, user-friendly operation interface, easy to use 9. Persistent EEPROM for saving configuration parameters and measurement data during power failure 10. Wide operation voltage range 11. Self-diagnosis

Technical Parameters:

Display LCD display, display various flow data in real-time, m³ or L display unit
Structure Embedded type design, integrated or split type
Measuring medium Liquid or solid-liquid, Conductivity> 0.5μs / cm2
Measuring Range 0.05m/s~8m/s
Measurement Accuracy Diameter  mm Range m/s Accuracy

3~20

0.3 or less ±0.25%FS
0.3~1 ±1.0%R
1~10 ±0.5%R

25~600

0.1~0.3 ±0.25%FS
0.3~1 ±0.5%R
1~10 ±0.3%R

700~3000

0.3 or less ±0.25%FS
0.3~1 ±1.0%R
1~10 ±0.5%R
%FS: relative range,  %R: relative measurement
Caliber(mm) 6mm~2000mm
Nominal pressure PN6, PN10, PN16, PN25, PN40, PN63, PN100, PN160, PN250, PN420 etc.
Output 4~20mA or frequency (<5KHz), RS485, wireless transmission (optional), relay (optional)
Connection DN6 ~ DN2000 for flange connection
Connection standard Applicable to various pipe flange standards
Product Standards Accuracy requirements meet JJG 1033-2007 standard
IP rating IP65(integrated), IP67 or IP68 when split (optional)
Power supply AC86~220V
Ambient temperature 5~55℃
Environment humidity <85%r.h(Non-condensing)

MD-EL Electromagnetic Flowmeter Related Video: